A Supplier of Crematories, Incinerators, Shredders, Autoclaves, and Used Oil Furnaces.
3053 Mountain View Way, Bessemer, AL 35020 Phone: (205) 428-0210 Fax: (205) 428-0211
Firelake Model 350 - 3 Pass Unit
Firelake’s three-pass heater models are easy to maintain with clean-out panels on both ends of the heat exchanger.
The three-pass heaters are also durable and designed for maximum heat transfer with 100% aluminized steel corrosion resistant alloy fire chamber and heat exchanger.
Model 350 SpecificationsInput (approx. BTU/hr.) 350,000 / 88,200 KCAL Output (approx. BTU/hr.) 300,000 / 75,600 KCAL Stack size 8" / 20.3 cm Shipping Weight 735 lbs./334 kg. Heater dimensions (L x W x H) 62" x 57" x 33" / 158 cm x143 x 84 Includes outside measurements of fan and burner Electrical requirements (maximum circuit protection) 115/60 30A (15A for export) Approx. fuel consumption 2.5 GPH Blower CFM 4700 Outlet Air Temperature 170 F Compressed air requirements 2 CFM @ 40 PSI / .057 m3/min.@.28Mpa Agency listings UL, ETLM, C-UL CSA Patents US: 5,067,894 utiliy, 331,104 des. CAN: Pat. 2,029,366, 69,374 des., 69,157 des. Fuels Crankcase oil, transmission and hydraulic fluids, as well as other petroleum-based lubricants (any weight combinations up to SAE 50 as well as #1 and #2 fuel oil.) Oil transfer pump 18 GPH @ 35 PSI (68 LPH @ .24 Mpa)