A Supplier of Crematories, Incinerators, Shredders, Autoclaves, and Used Oil Furnaces.
3053 Mountain View Way, Bessemer, AL 35020 Phone: (205) 428-0210 Fax: (205) 428-0211
Horizon 315 Single Pass Unit
The Many Advantages of the Horizon Single-Pass Heaters
Hozizon 315 SpecificationsInput (approx. BTU/hr.) 200,000 Output (approx. BTU/hr.) 160,000 Stack size 8" Shipping Weight 437 lbs./199 kg. Heater dimensions (L x W x H) 34.5" x 22" x 92.5"
Includes outside measurements of fan and burner
Duct Opening 16" x 16" Electrical requirements (maximum circuit protection) 30A (15A for export) Approx. fuel consumption 1.43 GPH Blower CFM 2550 Outlet Air Temperature 170 F Compressed air requirements 2 CFM @ 40 PSI Agency listings UL, C-UL Patents 5,950,616 Fuels Crankcase oil, transmission and hydraulic fluids, as well as other petroleum-based lubricants (any weight combinations up to SAE 50 as well as #1 and #2 fuel oil.) Oil transfer pump 18 GPH @ 35 PSI (68 LPH @ .24 Mpa)